Omd11 Manual - Deckma
Pre-alarm triggers at 2.5 %/m. Main Alarm triggers at 5.0 %/m. (These values are adjustable but rarely changed due to class approval).
The is a fixed-type oil content monitor designed for use on board vessels to monitor the oil content of bilge water, ballast water, or oily mixtures. It is most commonly integrated into Oily Water Separators (OWS) (such as those manufactured by Sunny Maritime or similar) to ensure that discharged water meets international regulatory limits (typically 15 ppm or 100 ppm). deckma omd11 manual
The most common maintenance task. The glass sample tube must be cleaned using a bottle brush and mild detergent to prevent "false high" readings caused by scaling or debris. Pre-alarm triggers at 2
You can access full digital versions of the OMD-11 instruction manual on several technical document platforms: The is a fixed-type oil content monitor designed
The Deckma OMD-11 Go to product viewer dialog for this item.